Products
SARS-CoV-2 Fluorescent PCR Kit
Five Advantages Of Products
- Triple detection to prevent missed detection: Simultaneous detection of the three genes of ORF1ab/E/N in 2019-nCoV, meeting the requirements of relevant documents of the World Health Organization (WHO)
- Add internal standard and monitor the whole process:For each test, an internal standard is added to the test reagent to prevent false negative test results.
- Simulate viruses to ensure quality:The positive control and internal standard of the kit are simulated RNA virus particles, which are closer to the detection of the virus structure, contain protein envelopes, and participate in the extraction with the sample at the same time, better monitor the entire experimental process and ensure the reliability of the test result
- Optimized processes, efficient and safe:Reagent and instrument matching verification to optimize the testing process. It takes only two hours from safe sample processing to stable testing data output, which improves the testing speed and protects the safety of front-line workers.
- Optimized processes, efficient and safe:Reagent and instrument matching verification to optimize the testing process. It takes only two hours from safe sample processing to stable testing data output, which improves the testing speed and protects the safety of front-line workers.
Product Details
2019-nCoV About The Program
Since mid-December 2019, cases of unexplained pneumonia with fever, fatigue,cough,and dyspnea as the main symptoms have occurred in Wuhan, China for a short period of time. Governments at all levels and administrative departments of health care attach great importance to quickly organizing Medical units and research institutes carry out investigations, treatments and collaborative research. Quickly determined the pathogen of these cases as new coronaviruses.
The World Health Organization (WHO) has confirmed and named it as 2019-nCoV, and the pneumonia caused by the pathogen infection is called Novel Coronavirus Pneumonia
Maccura 2019-nCoV Product Introduction
Extraction + Amplification
Two steps of detection: 1st step is to extract virus RNA from the sample. 2nd step is to perform RNA amplification. A total of two reagent products are needed, both of which are produced by Maccura. Note:Features of emergency approval products:1.The product validity period on the registration certificate is described as "tentatively valid for 6 months"
2.Registration certificate is valid for “1 year"
Q&A
Question: What are the prerequisites for users to carry out 2019-nCoV testing?
Answer:1.The user needs a special molecular laboratory.
2.A PCR amplification instrument with four channels or more is required.
3.An automatic nucleic acid extraction instrument is required. (If there is no full-automatic instrument, manual extraction is also possible, but the manual extraction process is more complicated, requiring technical staff to train customers, and manual extraction needs to provide auxiliary equipment such as a magnetic stand. Manual extraction is not recommended in the early stage, and the company waits for notification afterwards.)
Question:What types of PCR amplification equipment can match our reagents?
Answer:1.Theoretically,the instrument has four or more fluorescence detection channels.At present,it is clear:ABI 7500,ABI Q5,Roche Lightcycler 480II,Hongshi SLAN-96P,SLAN-96S
2.If the user does not have the above-mentioned instrument,the user's existing instrument model + picture can be fed back to the marketing department, and the marketing department will assist to determine whether the instrument can be used.Theoretically,Bio-rad,Hangzhou Bioer,and Xi'an Tianlong all have amplifiers with four channels or more.
Question: What are the end users of 2019-nCoV?
Answer: The main end users are the inspection department and the centers for Disease Control.
Question:What is the number of samples per hour for Maccura 2019-nCoV detection solution?
Answer:Extraction (Maccura Auto Extraction) + Amplification:96 samples in 2 hours
Shanghai ZhiBei Information Consulting Co., Ltd
Contact Person: Hunter Wang
Telephone: +86 18930727028
Landline: +86 18930727028
Company Address: Room 1603, Building 26,Lane 100,Chujia Road, Qingcun Town, Fengxian District, Shanghai, China
Factory Address: Room 1603, Building 26,Lane 100,Chujia Road, Qingcun Town, Fengxian District, Shanghai, China
Website: www.zhibeimas.com
Previous: No